Know everything physically happening to patient tissue in real time, all the time, from microtome to microscope.
Follow S1 to the microscopeProof for every patient.
Prova S1 lowered into hot water. Its light stays off until the slide senses the heat, then glows as the slide goes under.
Universal compatibility
One slide format. Many workflows.
S1 keeps the footprint of the slides you already run, so it travels the same path through the lab, recording as it goes.
-
01
Label
Slide printers
The case label prints on the frosted end. S1's own ID goes with it.
Leica IP S
Epredia SlideMate AS
Epredia SlideMate Laser
Primera Signature
Sakura Tissue-Tek SmartWrite
StatLab PiSmart S1
-
02
Section
Microtomes, cryostats and cytology prep
The ribbon is cut here, then floated onto S1. The record starts the moment tissue meets the slide.
Microtomes
Leica HistoCore AUTOCUT
Leica HistoCore MULTICUT
Epredia HM 355S
Sakura Tissue-Tek AutoSection
Cryostats
Leica CM1950
Epredia CryoStar NX70
Sakura Tissue-Tek Polar
Cytology slide prep
Hologic ThinPrep 5000
BD SurePath PrepStain
Epredia Cytospin 4
-
03
Float
Flotation baths
The section leaves the water on S1, and the slide starts its own record.
Leica HistoCore Water Bath M
Boekel Deluxe Lighted Tissue Flotation Bath
Epredia Digital Paraffin Flotation Bath
Leica HI1210
-
04
Dry and bake
Section dryers and ovens
Oven and dryer heat, and how long the slide sat in it.
CellPath High Capacity Section Dryer
CellPath Mini Section Dryer
Thermo Scientific Heratherm OGS60
-
05
Stain
IHC, H&E and special stainers
Every heated step, timed and temperature-logged. Every run, not every 90 days.
IHC and ISH
Leica BOND-PRIME
Leica BOND-III
Leica BOND-MAX
Roche BenchMark ULTRA PLUS
Roche BenchMark GX
Agilent Dako Omnis 165 Duo
Agilent Dako Autostainer Link 48
Sakura Tissue-Tek Genie
Biocare ONCORE Pro
Biocare intelliPATH+
Epredia Lab Vision Autostainer 360
Roche VENTANA DISCOVERY ULTRA
Biocare intelliPATH FLX
H&E and routine
Roche VENTANA HE 600
Leica HistoCore SPECTRA ST
Leica HistoCore CHROMAX ST
Leica ST5020 Multistainer
Sakura Tissue-Tek Prisma Plus
Epredia Gemini AS
Milestone PRESTO PRO
Roche VENTANA Symphony
Leica ST5010 Autostainer XL
Sakura Tissue-Tek DRS 2000
Special stains
Roche BenchMark Special Stains
Agilent Dako Artisan Link Pro
-
06
Coverslip
Coverslippers
Handling and motion through mounting, every move counted.
Leica HistoCore SPECTRA CV
Leica HistoCore CHROMAX CV
Leica CV5030
Sakura Tissue-Tek Glas g2
Sakura Tissue-Tek Film
Epredia ClearVue
-
07
Scan
Whole-slide scanners
Time to scan, and every bump on the way to the microscope.
Leica Aperio GT 450
Leica Aperio AT2
Roche VENTANA DP 200
Roche VENTANA DP 600
Hamamatsu NanoZoomer S360
Philips IntelliSite SG300
3DHISTECH Pannoramic 1000
ZEISS Axioscan 7
Epredia E1000 Dx
Motic EasyScan Infinity 100
Grundium Ocus 40
Huron TissueScope iQ
08
Microscope
The pathologist sees the tissue. S1 is built so the record of what it went through arrives with it.
Instrument names and illustrations show common slide workflows. They are trademarks of their respective owners, and Prova is not affiliated with or endorsed by them. Compatibility is a design goal and requires validation on each instrument.
For V1 labs
You prove the pads every 90 days. What proves the other 89?
V1 shows that each heating pad reached 93 °C and stayed under 99 °C. S1 is built to keep the whole curve for every drawer, so an exception tells you which drawer, when, and by how much.
Prova app concept. S1 is in development; the record shown is illustrative.
ULTRA PLUS heating-pad check
95 °C for 10 minutes, 30 drawers
Demonstration data
Not a tag. A recorder.
A label tells you which slide it is. S1 is built to tell you what happened to it, logged on the glass itself.
- Temperature
- Multi-point history, logged on the slide.
- Handling
- Every move, from microtome to microscope.
- Identity
- Linked to the instrument and the run.
- Memory
- Append-only. Read with any NFC phone.
Prova app
Read it with your phone.
Hold any NFC phone to S1. The Prova app shows what the slide went through, step by step, and flags anything outside your limits.
Hold to read
Bring the top of your phone to the slide.
Reading S1 · 0x7A3F-21C9
S1 · 0x7A3F-21C9
Case S26-04417 · Block A3 · Slide 2
- Float45.1 °C · 38 s
- Dry59.8 °C · 30 min
- StainRun 1182
- Scan6 bumps
Dry ran hot
S1 · 0x7A3F-22D0 · Oven 2
Prova Record
Append-only. Written on the slide as it happened.
sha256 9f2c 41e7 b0d3 77a1 5c9e 0b44 e2f8 1d6a
Prova app concept. S1 is in development; screens and values are illustrative.
A standard slide that keeps its own record.
- 75 × 25 mm. The footprint of the slides you already run.
- Drop-in. Built for existing racks, stainers and scanners.
- Any phone. Tap to read with the Prova app.
- No IT project. Nothing to install on your network.
Planned capabilities. Initial scope: blank and control slides. Performance and instrument compatibility require validation.
Your S1 demo kit is on us.
Order V1 and we'll send your lab a complimentary Prova S1 demo kit as S1 becomes available. One kit per lab.
Order V1